Used on water boilers. 120VAC. Interrupts power immediately in a low water condition. Burner circuit locks-out if water remains below probe for 30 seconds. Manual reset will not trip due to power failures. Test button checks burner circuit to ensure proper control operation and lock-out function without lowering the water level.

    Manual Reset
    Burner Circuit Test Button
    LED Indicating Lights
    Meets ASME CSD-1 Requirements for Commercial Water Boilers
    Power Consumption: 4 VA
    Switching Capacity: 5.8 FLA, 34.8 LRA
    Switch Contacts: SPDT
    Max Pressure: 160 PSI
    Voltage: 120VAC
    Model: 550
$89.10

Original: $254.56

-65%
Hydrolevel 550 - Model 45-550 LWCO 120V w/ Manual Reset for Water Boilers

$254.56

$89.10

Hydrolevel 550 - Model 45-550 LWCO 120V w/ Manual Reset for Water Boilers

Used on water boilers. 120VAC. Interrupts power immediately in a low water condition. Burner circuit locks-out if water remains below probe for 30 seconds. Manual reset will not trip due to power failures. Test button checks burner circuit to ensure proper control operation and lock-out function without lowering the water level.

    Manual Reset
    Burner Circuit Test Button
    LED Indicating Lights
    Meets ASME CSD-1 Requirements for Commercial Water Boilers
    Power Consumption: 4 VA
    Switching Capacity: 5.8 FLA, 34.8 LRA
    Switch Contacts: SPDT
    Max Pressure: 160 PSI
    Voltage: 120VAC
    Model: 550

Product Information

Shipping & Returns

Description

Used on water boilers. 120VAC. Interrupts power immediately in a low water condition. Burner circuit locks-out if water remains below probe for 30 seconds. Manual reset will not trip due to power failures. Test button checks burner circuit to ensure proper control operation and lock-out function without lowering the water level.

    Manual Reset
    Burner Circuit Test Button
    LED Indicating Lights
    Meets ASME CSD-1 Requirements for Commercial Water Boilers
    Power Consumption: 4 VA
    Switching Capacity: 5.8 FLA, 34.8 LRA
    Switch Contacts: SPDT
    Max Pressure: 160 PSI
    Voltage: 120VAC
    Model: 550